This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.


  • Subject: [LDM #UYH-624598]: LVS realserver switching loses data
  • Date: Thu, 26 Oct 2006 10:24:08 -0600

I don't know, Art.  Given that Ls2 is running LDM 6.4.5, gets CONDUIT data
from one upstream LDM, and reconnected to the same LDM... it should not have
missed any data-products.  Unless the product-queue on Iddrs2 was too small
and the product-latency so high that the missing products were purged from
the queue before they could be sent.  I note that Ls2 requested data from
about 40 minutes before the reconnection.  Does the age of the oldest
product in the queue on Iddrs2 ever drop below one hour?  If you say no,
then I want to know how you know.

Regards,
Steve Emmerson