This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Mike, I infer the following from the MRTG and the rtstats(1) plots for SonomaTech: 1) the SonomaTech LDM restarted around noon WDT on the 18th; 2) it saturated the pipe; 3) it didn't catch up until just before 1700 WDT; 4) throughout the subsequent night, the pipe was occationally saturated; and 5) the pipe became saturated again around the start of the workday at SonomaTech. Judging from this and the good performace of the LDM in sending the same data-products from Rossby to here, I think it's safe to say that SonomaTech's pipe just isn't big enough to receive the data-products that it's requesting. Merging all the requests into one was done to validate the hypothesis that a SonomaTech router was favoring higher-volume LDM connections at the expense of lower-volume ones. That appears to be the case. SonomaTech needs to either reduce the data that it requests or get a bigger pipe, in my opinion. Regards, Steve Emmerson Ticket Details =================== Ticket ID: XXW-990118 Department: Support LDM Priority: Normal Status: Closed