[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[LDM #PNL-985883]: Trouble receiving WSI push data with LDM 6.4.5
- Subject: [LDM #PNL-985883]: Trouble receiving WSI push data with LDM 6.4.5
- Date: Thu, 17 Aug 2006 11:41:21 -0600
Art,
> I contacted WSI. They said they're getting segmentation faults/core dumps
> but don't know yet what the cause is. Their expert guy is out today, so
> it may be tomorrow until it's figured out. I told them to contact Unidata
> directly if they have questions about how their software is playing with
> the current LDM.
Interesting! LDM 6 should be backward-compatible with LDM 5 protocols --
but the latest version has problems getting ACCEPT data-products
from WSI. The problem could lie with the latest version, or it could
lie with WSI.
You say it does, eventually, receive the data-products, only they're
significantly delayed. Intriguing.
STOP THE PRESSES! I just noticed this entry in the LDM change-log file:
Moved initialization of autoshift module to accomodate incoming
HIYA connections that start sending data-products regardless of
a RECLASS reply. This solves a problem receiving data from WSI.
Would you mind installing beta-version 6.4.6.4? This should solve your
problem. It's available at
ftp://ftp.unidata.ucar.edu/pub/ldm/beta/ldm-6.4.6.4.tar.Z
Regards,
Steve Emmerson
Ticket Details
===================
Ticket ID: PNL-985883
Department: Support LDM
Priority: Normal
Status: Closed