This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.


  • Subject: [IDV #BEW-121151]: IDV - Changing Display Type on Value Plots Views
  • Date: Mon, 21 Sep 2020 11:46:47 -0600

> Hi,
> 
> I'm plotting Surface Temperatures from model data for a project and am
> trying to find a way to change the Value Plots view display type to
> Fahrenheit or Celsius and not Kelvin.
> 
> I am able to do this with Fill/Contour types but I cannot find the option
> to change Kelvin to Fahrenheit & Celcius in the Value Plots section.
> 
> Is there something I'm not seeing or a workaround?
> 
> 
> Thank You!
> James
> 
> 
Hi James,

It is very easy to change the display unit. In the display control panel, the 
drop-down menu:
Edit > Change Display UNIT... SEE the attached.


YUAN