This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
> Dear IDV support, > > We are using IDV to represent in 3D mode, outputs from meteorological and > oceanographic circulation models. > > Both our models work in sigma coordinates. At the moment we can calculate > the z-level equivalent from the ocean model file outside IDV. > > Is there a way of converting from Sigma to Zlevel (altitude in meters) > Inside IDV, the meteorological files? The meteorological model is MM5 > Carlos, The answer is yes, but no a good idea to let the IDV doing this kind of translation. The IDV can handle sigma coordinate system, and you may not need to convert the to the z level depending on the requirement. Yuan > The sigma levels in our MM5 meteorological files: > .05 .125 .175 .225 .275 .325 .375 .425 .465 .49 .51 .535 .575 .625 .675 > .725 .775 .825 .89 .92 .95 .97 .985 .995 > > > Thanks in advance. > > Carlos Lucas > > Ticket Details =================== Ticket ID: NNP-883811 Department: Support IDV Priority: Normal Status: Closed