[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[IDV #ZJC-641381]: IDV - VGEE IDV
- Subject: [IDV #ZJC-641381]: IDV - VGEE IDV
- Date: Mon, 11 Dec 2006 11:37:37 -0700
> I was working with the new Jython Diplay Control, and ran into a small
> problem. The sampleIndex seems to return a data type that can only be
> converted into a string, and not a float or double. This prevents me
> from using the value in other forms (read: my own model).
>
> 1) Can you add something in the function that allow a user to specifiy
> how the data from the probe should be returned?
The return value from the sample call is a visad object.
If you are using a point probe and are sampling at the animation time
(and if there are actually times in the display) then you will get a VisAD
Real object. If there are no times then the sampleAtTime just samples spatially
and will return a VisAD FieldImpl object. Likewise, the other probe types
will give some structure (e.g., a FlatField).
To access the value of a Real you can do:
sample.getValue();
which will return the (double) value of the Real in its native units.
> 2) How do I best use the incl. jtyhon procedure you added the allow the
> user to specify new input data (by presenting the data selector GUI),
> something like: "displayControl.addEditMenuItem('Change
> parameter','addNewData');" ?
The menu call back routine specified in the menu items is a jython routine.
So you could do the above which will result in a call to the jython routine
addNewData. addNewData can then call back to the displayControl. e.g.:
def addNewData (displayControl):
displayControl.selectData('Add new parameter');
Note: I changed the methods on the Jython control for selecting data.
They are:
public void addData(String message);
public void addData(String message, String callback);
public void replaceData(String message);
public void replaceData(String message, String callback);
If no call back is specified then it defaults to 'handleData'
If the user does choose something new then the call back routine
is called.