This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi Russ, re: lack of NEXRAD data from SSEC NOAAPort ingest machines > That seems to have fixed the problem. We reset the viterbi boxes > and the error rates are now in acceptable range. We did have a TRW this > AM at about the same time that the problem started. I'm wondering if > that could have caused the problem. Perhaps, but I would keep checking the viterbi bit error rate on your Novra S75 box(es) for the next few days. I say this because I checked ours earlier today, and it was back to showing ~10**-5. A reset put that back to 0.00 which is where it should be. I have learned from chatter on a Yahoo group NOAAPort list and directly from Gilbert Sebenste (NIU) that the newer Novra unit, the S75+, is much better at keeping a signal lock when upgraded to the latest firmware. Unfortunately, there is no correspondingly new firmware for our older S75 units. Cheers, Tom -- **************************************************************************** Unidata User Support UCAR Unidata Program (303) 497-8642 P.O. Box 3000 address@hidden Boulder, CO 80307 ---------------------------------------------------------------------------- Unidata HomePage http://www.unidata.ucar.edu **************************************************************************** Ticket Details =================== Ticket ID: GTV-595062 Department: Support IDD Priority: Normal Status: Closed