This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
>From: Robert Mullenax <address@hidden> >Organization: UCAR/Unidata >Keywords: 200404141548.i3EFmuCT021406 >Ever since the switch to 24-bit color, you can no longer change radar >enhancements >on NIDS products in GARP. Satellite works fine, and sat and rad both in >NMAP2 work. >I realize this isn't a huge problem in the overall scheme of things but it >was nice to >be able to take out various dBz levels and put them back in. Is there an >easy workaround >for this. NMAP2 isn't as desirable because there is no cursor read out of >dBz values. >(that would be nice as well). > >Thanks, >Robert Mullenax > Robert, It seems to me that the issue is that the code completely ignores the setting of radenhancetbl in $GARPHOME/config/Garp_defaults. In fact, there is no place in the code to use any key other than satenhancetbl. Steve Chiswell Unidata User Support -- NOTE: All email exchanges with Unidata User Support are recorded in the Unidata inquiry tracking system and then made publically available through the web. If you do not want to have your interactions made available in this way, you must let us know in each email you send to us.