This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Stonie, The sounder images in GINI I last looked had nothing in the calibration block, but I'd be willing to look at it. Does you copy of the NESDIS interface control document give the format? Steve >From: "Stonie R. Cooper" <address@hidden> >Organization: Planetary Data, Incorporated >Keywords: 200308151611.h7FGB7Ld022972 >Steve, > >Actually, GINI does have a calibration block . . . it's just never used. If I > >preprocessed the GINI to have the necessary conversion, does GEMPAK >understand the calibration block in GINI? > >Stonie > >On Friday 15 August 2003 16:05, Steve Chiswell wrote: >> Stonie, >> >> The AREA files in the UNIWISC IDD feed have calibration information, so the >> units and values are shown in the image bar. This includes the sounder >> channel products which are also in the NOAAPORT sbroadcast as GINI images. >> >> The GINI images in the NOAAPORT broadcast do not have a calibration block, >> so unless you were to use an external table for the GINIs (similar to what >> I did for the radar composites I create in GINI format for the FNEXRAD >> feed) the programs do not have theinformation to plot units/values other >> than the pixel values. >> >> Steve Chiswell >-- >Stonie R. Cooper >Planetary Data, Incorporated >(402) 782-6611 >