This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Dale, The values are: .1, .4, 1., 2., 4., 7., 10., 16., 24., 32., 40. Where 4 g/kg is the line just slightly warmer than 0C at 1000mb. Steve Chiswell >From: Dale Morris <address@hidden> >Organization: UCAR/Unidata >Keywords: 200303141733.h2EHXmB2013945 >I have been using GEMPAK's snprof program to generate some skewt plots. >I was wondering what the default values for the mixing ratio lines are. > >Thanks, > >Dale Morris >Program Manager for Public Safety >Oklahoma Climate Survey >University of Oklahoma > >