[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[LDM #BXP-294837]: How to make a change in ldmd.conf
- Subject: [LDM #BXP-294837]: How to make a change in ldmd.conf
- Date: Thu, 30 Jul 2015 13:28:20 -0600
Hi James,
re:
> This morning, I followed Unidata's instruction for picking up various
> Conduit data EXCEPT 0.25 degree GFS output.
>
> REQUEST CONDUIT "ncep/[^G]" /upstream.host.name/
> REQUEST CONDUIT "gfs.*[012]p[^2]" /upstream.host.name
>
> At least for me, I didn't get any of the Conduit GFS Ensemble data. How
> can I modify the first request line to include receiving GEFS data?
Here is the REQUEST line that a user at CSU reported worked for him:
REQUEST CONDUIT "(ge[cp][0-9][0-9]).t[0-2][0-9]z.*" upstream.host.name
We apologize for this hiccup!
Cheers,
Tom
--
****************************************************************************
Unidata User Support UCAR Unidata Program
(303) 497-8642 P.O. Box 3000
address@hidden Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage http://www.unidata.ucar.edu
****************************************************************************
Ticket Details
===================
Ticket ID: BXP-294837
Department: Support CONDUIT
Priority: Normal
Status: Closed